SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Approval Agency DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal)
3120-N521-P7T1-W02D-10A E-T-A 3120-N521-P7T1-W02D-10A 37.4700
RFQ
ECAD 11 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N521-P7T1-W02D-10A EAR99 8536.20.0020 10 Thermal 10A 415 V 50 V Rocker 2 None -
8345-B22A-V3M2-DB1B1B-10A E-T-A 8345-B22A-V3M2-DB1B1B-10A 168.6040
RFQ
ECAD 9758 0.00000000 E-T-A 8345 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 10A 480 V 80 V Lever 2 None -
3120-N524-P7T1-W01D-20A E-T-A 3120-N524-P7T1-W01D-20A 37.7060
RFQ
ECAD 2374 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N524-P7T1-W01D-20A EAR99 8536.20.0020 10 Thermal 20A 415 V 50 V Rocker 2 None -
2210-S211-P1M1-Z141-5A E-T-A 2210-S211-P1M1-Z141-5A 66.1300
RFQ
ECAD 1069 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 5A 480 V 65 V Lever 1 None -
3300-IG2-K20-15A E-T-A 3300-IG2-K20-15A 68.1570
RFQ
ECAD 4741 0.00000000 E-T-A 3300 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal Magnetic 15A 250 V 80 V Push to Reset 1 None -
2210-T220-K0M1-H231-25A E-T-A 2210-T220-K0M1-H231-25A 82.2900
RFQ
ECAD 3188 0.00000000 E-T-A 2210-T2 Bulk Active DIN Rail CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 25A 480 V 65 V Lever 2 None -
3300-IG2-P10-0.4A E-T-A 3300-IG2-P10-0.4A 67.4840
RFQ
ECAD 4992 0.00000000 E-T-A 3300 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal Magnetic 400mA 250 V 80 V Push to Reset 1 None -
452-2-K34-FN2-75A E-T-A 452-2-K34-FN2-75A 421.2700
RFQ
ECAD 5836 0.00000000 E-T-A 452 Bulk Active Panel Mount CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 75A 28 V Push-Pull Plunger 1 None -
8345-B01A-V3M1-DB1B1B-X8345-F01X12402M-100A E-T-A 8345-B01A-V3M1-DB1B1B-X8345-F01X12402M-100A 130.4580
RFQ
ECAD 9102 0.00000000 E-T-A 8345 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 100A 480 V 80 V Lever 1 None -
3120-N321-P7T1-W12DY3-10A E-T-A 3120-N321-P7T1-W12DY3-10A 38.8270
RFQ
ECAD 3681 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N321-P7T1-W12DY3-10A EAR99 8536.20.0020 10 Thermal 10A 415 V 50 V Rocker 2 White 115V
3120-F621-P7T1-W09D-1A E-T-A 3120-F621-P7T1-W09D-1A -
RFQ
ECAD 5485 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 1A 250 V 50 V Rocker 2 None -
483-G222-J1M1-B2S0ZN-2A E-T-A 483-G222-J1M1-B2S0ZN-2A 215.8700
RFQ
ECAD 6545 0.00000000 E-T-A 483 Bulk Active Panel Mount CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 2A 115 V 28 V Push-Pull Plunger 1 None -
3120-F321-P7T1-W15D-15A E-T-A 3120-F321-P7T1-W15D-15A -
RFQ
ECAD 6066 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 15A 250 V 50 V Rocker 2 Orange -
4230-T130-K0BE-15A E-T-A 4230-T130-K0BE-15A 34.7600
RFQ
ECAD 1097 0.00000000 E-T-A 4230-T Bulk Active DIN Rail CSA C22.2 No 235, UL489 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 15A 480 V 125 V Lever 3 None -
2210-T230-K0T1-H231-15A E-T-A 2210-T230-K0T1-H231-15A 112.6100
RFQ
ECAD 4505 0.00000000 E-T-A 2210-T2 Bulk Active DIN Rail CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 15A 480 V 65 V Lever 3 None -
3120-F321-H7T1-W19DG4-8A E-T-A 3120-F321-H7T1-W19DG4-8A -
RFQ
ECAD 2458 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 8A 250 V 50 V Rocker 2 Green 185V
X1180-01-ST201-0.5A-B E-T-A X1180-01-ST201-0.5A-B 23.9200
RFQ
ECAD 8422 0.00000000 E-T-A X1180 Bulk Active Holder CSA C22.2 No 235, UL1059, UL1077, UL786E, VDE - Not Applicable 302-X1180-01-ST201-0.5A-B 1 Thermal 500mA 250 V 72 V Pushbutton 1 None -
2210-S221-P1T1-Z241-0.1A E-T-A 2210-S221-P1T1-Z241-0.1A 82.2900
RFQ
ECAD 2554 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 100mA 480 V 65 V Lever 2 None -
1110-F212-P1M1-0.5A E-T-A 1110-F212-P1M1-0.5A 19.5536
RFQ
ECAD 1253 0.00000000 E-T-A 1110 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 50 Thermal 500mA 250 V 50 V Push-Push 1 None -
2210-S221-P1T1-H0-12A E-T-A 2210-S221-P1T1-H0-12A 219.9600
RFQ
ECAD 8756 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 12A 480 V 65 V Lever 2 None -
2-6400-IG8-P10-A3-SI-401041 E-T-A 2-6400-IG8-P10-A3-SI-401041 -
RFQ
ECAD 9043 0.00000000 E-T-A 2-6400 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal - 250 V 28 V Push to Reset 1 None -
8340-F920-P1M2-BHH0-30A E-T-A 8340-F920-P1M2-BHH0-30A 133.4110
RFQ
ECAD 5647 0.00000000 E-T-A 8340-F Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 30A 240 V 80 V Lever 2 None -
3131-CF1HT-000000-3Y2-15A E-T-A 3131-CF1HT-000000-3Y2-15A 26.2340
RFQ
ECAD 2864 0.00000000 E-T-A 3131 Bulk Active Panel Mount IEC 60934, UL1077, UL1500 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 15A 240 V 28 V Not Included 1 Yellow 10 ~ 14V
4230-T130-K0CE-50A E-T-A 4230-T130-K0CE-50A 34.7400
RFQ
ECAD 5 0.00000000 E-T-A 4230-T Bulk Active DIN Rail CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 50A 480 V 125 V Lever 3 None -
3120-F521-P7T1-W02D-5A E-T-A 3120-F521-P7T1-W02D-5A -
RFQ
ECAD 3844 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 5A 250 V 50 V Rocker 2 None -
2210-S231-P1M1-Z241-10A E-T-A 2210-S231-P1M1-Z241-10A 112.6100
RFQ
ECAD 7553 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 10A 480 V 65 V Lever 3 None -
127-F11-P10-H-KF-6A E-T-A 127-F11-P10-H-KF-6A 36.9220
RFQ
ECAD 1707 0.00000000 E-T-A 127 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 6A 250 V 50 V Push to Reset 1 None -
2210-S231-P1M1-Z241-0.6A E-T-A 2210-S231-P1M1-Z241-0.6A 112.6100
RFQ
ECAD 3036 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 600mA 480 V 65 V Lever 3 None -
3120-N321-P7T1-W04D-20A E-T-A 3120-N321-P7T1-W04D-20A 33.4650
RFQ
ECAD 7235 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N321-P7T1-W04D-20A EAR99 8536.20.0020 10 Thermal 20A 415 V 50 V Rocker 2 None -
106-M2-P33-2A E-T-A 106-M2-P33-2A -
RFQ
ECAD 9879 0.00000000 E-T-A 106 Bulk Active Panel Mount CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 50 Thermal 2A 240 V 48 V Push to Reset 1 - -
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse