Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Approval Agency DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal)
3300-IG8-P10-1A E-T-A 3300-IG8-P10-1A 65.1390
RFQ
ECAD 3340 0.00000000 E-T-A 3300 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal Magnetic 1A 250 V 80 V Push to Reset 1 None -
3120-N311-P7T1-W14XR4-5A E-T-A 3120-N311-P7T1-W14XR4-5A 27.3920
RFQ
ECAD 8648 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N311-P7T1-W14XR4-5A EAR99 8536.20.0020 10 Thermal 5A 415 V 50 V Rocker 1 Red 230V
3120-F323-P7T1-W01D-5A E-T-A 3120-F323-P7T1-W01D-5A -
RFQ
ECAD 3600 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 5A 250 V 50 V Rocker 2 None -
2210-T210-K0M1-H131-1.5A E-T-A 2210-T210-K0M1-H131-1.5A 51.4300
RFQ
ECAD 9398 0.00000000 E-T-A 2210-T2 Bulk Active DIN Rail CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 1.5A 480 V 65 V Lever 1 None -
1410-F110-P1F1-W14QB2-0.63A E-T-A 1410-F110-P1F1-W14QB2-0.63A 17.1296
RFQ
ECAD 8643 0.00000000 E-T-A 1410-F1 Bulk Active Panel Mount CSA C22.2 No 235, UL1077 download RoHS Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 50 Thermal 630mA 250 V 48 V Rocker 1 Red 28V
3600-P10-SI-3.5A E-T-A 3600-P10-SI-3.5A 94.7270
RFQ
ECAD 4389 0.00000000 E-T-A 3600 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal Magnetic 3.5A 250 V 65 V Push to Reset 1 None -
9510-G213-J3F1-B2C2B1-2.5A E-T-A 9510-G213-J3F1-B2C2B1-2.5A 137.4460
RFQ
ECAD 6923 0.00000000 E-T-A 9510 Bulk Active Panel Mount - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic 2.5A 5 V 28 V Push-Pull Plunger 1 None -
4230-T120-K0CE-7A E-T-A 4230-T120-K0CE-7A 23.4300
RFQ
ECAD 43 0.00000000 E-T-A 4230-T Bulk Active DIN Rail CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 7A 480 V 125 V Lever 2 None -
3120-N311-P7T1-W01D-4A E-T-A 3120-N311-P7T1-W01D-4A 22.0300
RFQ
ECAD 7050 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N311-P7T1-W01D-4A EAR99 8536.20.0020 10 Thermal 4A 415 V 50 V Rocker 1 None -
3120-F31A-H7T1-W12LY3-1A E-T-A 3120-F31A-H7T1-W12LY3-1A -
RFQ
ECAD 1895 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 1A 250 V 50 V Rocker 1 None -
2210-S231-P1T1-Z241-12A E-T-A 2210-S231-P1T1-Z241-12A 112.6100
RFQ
ECAD 5119 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 12A 480 V 65 V Lever 3 None -
3120-N321-P7T1-W14DR3-10A E-T-A 3120-N321-P7T1-W14DR3-10A 38.8270
RFQ
ECAD 1807 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N321-P7T1-W14DR3-10A EAR99 8536.20.0020 10 Thermal 10A 415 V 50 V Rocker 2 Red 115V
2-5700-IG1-P10-A3-DD-0.1A E-T-A 2-5700-IG1-P10-A3-DD-0.1A -
RFQ
ECAD 2080 0.00000000 E-T-A 2-5700 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 100mA 250 V 50 V Push-Push 1 None -
4130-G211-K4M1-50A E-T-A 4130-G211-K4M1-50A 65.9020
RFQ
ECAD 6131 0.00000000 E-T-A 4130 Bulk Active Panel Mount CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 50A 240 V 50 V Push to Reset 1 None -
105-P30-5A E-T-A 105-P30-5A 17.1620
RFQ
ECAD 3565 0.00000000 E-T-A 105 Bulk Active Panel Mount CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 50 Thermal 5A 240 V 48 V Push to Reset 1 - -
9510-M213-P1F1-Z0R2R1-15A E-T-A 9510-M213-P1F1-Z0R2R1-15A 105.6470
RFQ
ECAD 9447 0.00000000 E-T-A 9510 Bulk Active Panel Mount - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic 15A 5 V 28 V Push-Pull Plunger 1 None -
3900-P10-SI-10A E-T-A 3900-P10-SI-10A 97.0620
RFQ
ECAD 1827 0.00000000 E-T-A 3900 Bulk Active Panel Mount IEC 60934 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal Magnetic 10A 250 V 65 V Push to Reset 1 None -
412-K14-FN2-15A E-T-A 412-K14-FN2-15A 111.6300
RFQ
ECAD 8959 0.00000000 E-T-A 412 Bulk Active Panel Mount CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 15A 115 V 28 V Push-Pull Plunger 1 None -
3120-N323-P7T1-W02D-4A E-T-A 3120-N323-P7T1-W02D-4A 33.4650
RFQ
ECAD 9083 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N323-P7T1-W02D-4A EAR99 8536.20.0020 10 Thermal 4A 415 V 50 V Rocker 2 None -
483-G533-J1M1-B2S0ZN-3A E-T-A 483-G533-J1M1-B2S0ZN-3A 215.8700
RFQ
ECAD 4846 0.00000000 E-T-A 483 Bulk Active Panel Mount CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 3A 115 V 28 V Push-Pull Plunger 1 None -
3120-N324-P7T1-W15LY4-1.2A E-T-A 3120-N324-P7T1-W15LY4-1.2A 54.0490
RFQ
ECAD 9626 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N324-P7T1-W15LY4-1.2A EAR99 8536.20.0020 10 Thermal 1.2A 415 V 50 V Rocker 2 Orange 230V
3130-F120-P7T1-W01Q-0.5A E-T-A 3130-F120-P7T1-W01Q-0.5A 49.1770
RFQ
ECAD 5698 0.00000000 E-T-A 3130-F Bulk Active Panel Mount CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 500mA 250 V 50 V Rocker 2 None -
3120-N521-H7T1-W01X-3A E-T-A 3120-N521-H7T1-W01X-3A -
RFQ
ECAD 1026 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N521-H7T1-W01X-3A EAR99 8536.20.0020 10 Thermal 3A 415 V 50 V Rocker 2 None -
1658-G41-02-S83-055800-6A E-T-A 1658-G41-02-S83-055800-6A 4.2986
RFQ
ECAD 5252 0.00000000 E-T-A 1658 Bulk Active Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 6A 240 V 28 V Push to Reset 1 None -
2210-S231-P1M1-H0-12A E-T-A 2210-S231-P1M1-H0-12A 313.4200
RFQ
ECAD 8778 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 12A 480 V 65 V Lever 3 None -
3120-F621-P7T1-W02L-6A E-T-A 3120-F621-P7T1-W02L-6A -
RFQ
ECAD 5052 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 6A 250 V 50 V Rocker 2 None -
1658-G21-00-P10-D01-12A E-T-A 1658-G21-00-P10-D01-12A -
RFQ
ECAD 4276 0.00000000 E-T-A 1658 Bulk Obsolete Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 12A 240 V 28 V Push to Reset 1 None -
1658-G21-01-P10-D01-055810-5A E-T-A 1658-G21-01-P10-D01-055810-5A 4.2066
RFQ
ECAD 3352 0.00000000 E-T-A 1658 Bulk Active Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 5A 240 V 28 V Push to Reset 1 None -
8340-F110-P1K1-A2H0-30A E-T-A 8340-F110-P1K1-A2H0-30A 70.3570
RFQ
ECAD 2608 0.00000000 E-T-A 8340-F Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 30A 240 V 80 V Toggle 1 None -
3120-F521-P7T1-W19DG4-20A E-T-A 3120-F521-P7T1-W19DG4-20A -
RFQ
ECAD 8710 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 20A 250 V 50 V Rocker 2 Green 230V