Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Mounting Type | Type | Features | Base Product Number | Accessory Type | For Use With/Related Products | Approval Agency | Ingress Protection | Length | Power - Rated | Termination Style | Weight | Specifications | Voltage - Supply | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Controller Type | Housing Material | Lamp Type | Number of Inputs and Type | Contact Rating @ Voltage | Lens Type | Number of Stacks | Light Color | Function - Lighting | Function - Audible | Safety Outputs and Type | Auxiliary Outputs and Type | Safety Category | Illumination Color | Luminous Flux | Profile (W x H) | Rated Life | Protection | Detection Capability | Protective Height | Number of Beams | Beam Pitch | Operating Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TL70GGYRB | 491.0000 | ![]() |
7022 | 0.00000000 | Banner Engineering Corporation | TL70 | Box | Active | -40°C ~ 50°C | Complete Unit | Dip Switch | TL70GG | IP65 - Dust Tight, Water Resistant | Wire Leads | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | LED | 5 | Blue, Green, Red, Yellow | Steady | - | ||||||||||||||||||||||||||||||
![]() |
TL50BLW2Y2R2ALS3CQ | - | ![]() |
1713 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Obsolete | -20°C ~ 50°C | Complete Unit | Alarm | TL50BL | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | OBSOLETE | 1 | LED | 3 | Red, White, Yellow | Flashing | Pulse | |||||||||||||||||||||||||||||
![]() |
CL50GRXALSNQ | 197.0000 | ![]() |
2792 | 0.00000000 | Banner Engineering Corporation | CL50 | Bulk | Active | -20°C ~ 50°C | Complete Unit | Alarm | CL50GR | IP67 - Dust Tight, Waterproof | M12 | - | 18 ~ 30VDC | download | 2170-CL50GRXALSNQ | 1 | LED | 2 | Green, Red | Steady | Continuous | |||||||||||||||||||||||||||||||
![]() |
TL70BGYRACQP | 480.0000 | ![]() |
8409 | 0.00000000 | Banner Engineering Corporation | TL70 | Box | Active | -40°C ~ 50°C | Complete Unit | Alarm, Dip Switch | TL70BG | IP65 - Dust Tight, Water Resistant | M12 | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | LED | 5 | Blue, Green, Red, Yellow | Steady | Multiple | ||||||||||||||||||||||||||||||
![]() |
TL50CGYRQ | 177.0000 | ![]() |
3189 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -40°C ~ 50°C | Complete Unit | - | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | EAR99 | 8531.80.9051 | 1 | LED | 3 | Green, Red, Yellow | - | - | |||||||||||||||||||||||||||||
![]() |
TL50WALSQ | 162.0000 | ![]() |
7090 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | Alarm | IP67 - Dust Tight, Waterproof | Connector | - | 18 ~ 24VAC, 30VDC | - | Not Applicable | REACH Unaffected | 1 | LED | 2 | White | - | Continuous | |||||||||||||||||||||||||||||||
![]() |
CL50GRXAN | 176.0000 | ![]() |
9658 | 0.00000000 | Banner Engineering Corporation | CL50 | Bulk | Active | -20°C ~ 50°C | Complete Unit | Alarm | CL50GR | IP50 - Dust Protected | Cable Leads | - | 18 ~ 30VDC | download | 2170-CL50GRXAN | 1 | LED | 2 | Green, Red | Steady | Continuous | |||||||||||||||||||||||||||||||
![]() |
SC22-3-CU1 | - | ![]() |
4227 | 0.00000000 | Banner Engineering Corporation | SC22 | Box | Obsolete | - | DIN Rail | Display | SC22 | - | IP20 | Screw Terminal | - | 24VDC | - | 1 (Unlimited) | REACH Unaffected | OBSOLETE | 1 | General Purpose | 22 - Digital | 0.75A @ 24VDC | - | - | Category 4, PLe, SIL3 | |||||||||||||||||||||||||||
![]() |
TL70WBGYRAQP | 580.0000 | ![]() |
1345 | 0.00000000 | Banner Engineering Corporation | TL70 | Box | Active | -40°C ~ 50°C | Complete Unit | Alarm, Dip Switch | TL70WB | IP65 - Dust Tight, Water Resistant | M12 | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | LED | 6 | Blue, Green, Red, White, Yellow | Steady | Multiple | ||||||||||||||||||||||||||||||
![]() |
TL50HBCQ | 113.0000 | ![]() |
7 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -40°C ~ 50°C | Complete Unit | - | TL50HB | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 18 ~ 30VDC | - | 1 (Unlimited) | REACH Unaffected | EAR99 | 8531.80.9051 | 1 | LED | 1 | Blue | Steady | - | ||||||||||||||||||||||||||||
![]() |
TL50BLRG | 191.0000 | ![]() |
3 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -40°C ~ 50°C | Complete Unit | - | TL50BL | IP67 - Dust Tight, Waterproof | Wire Leads | - | 12 ~ 30VDC | - | 1 (Unlimited) | REACH Unaffected | EAR99 | 8531.80.9051 | 1 | LED | 2 | Green, Red | Steady | - | ||||||||||||||||||||||||||||
![]() |
TL50HGYRAOS3Q | 312.0000 | ![]() |
3 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | Alarm | TL50HG | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 18 ~ 30VDC | - | 1 (Unlimited) | REACH Unaffected | EAR99 | 8531.80.9051 | 1 | LED | 3 | Green, Red, Yellow | Steady | Multiple | ||||||||||||||||||||||||||||
![]() |
TL50BLG1Y1R1ALSQ | 341.0000 | ![]() |
5974 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | Alarm | TL50BL | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | EAR99 | 8531.80.9041 | 1 | LED | 3 | Green, Red, Yellow | Rotating | Continuous | ||||||||||||||||||||||||||||
![]() |
TL50BLY1Y1CQ | - | ![]() |
4020 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Obsolete | -20°C ~ 50°C | Complete Unit | - | TL50BL | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | OBSOLETE | 1 | LED | 2 | Yellow | Rotating | - | |||||||||||||||||||||||||||||
![]() |
TL50WBYRQ | 197.0000 | ![]() |
8933 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -40°C ~ 50°C | Complete Unit | - | TL50WB | IP67 - Dust Tight, Waterproof | Connector | - | 18 ~ 24VAC, 30VDC | - | Not Applicable | REACH Unaffected | 1 | LED | 4 | Blue, Red, White, Yellow | Steady | - | ||||||||||||||||||||||||||||||
![]() |
XS8SI | 327.0000 | ![]() |
1 | 0.00000000 | Banner Engineering Corporation | XS | Bulk | Active | 0°C ~ 55°C | DIN Rail | - | CE, cULus, UL | IP20, IP54 | Screw Terminal | - | 24VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8537.10.9160 | 1 | Expansion Module | 8 - Digital | - | - | - | Category 4, PLe, SIL3 | ||||||||||||||||||||||||||
![]() |
EZSS-450 | 79.0000 | ![]() |
2616 | 0.00000000 | Banner Engineering Corporation | EZSS | Box | Active | EZSS | Guard | EZ-SCREEN Series | - | download | 1 (Unlimited) | REACH Unaffected | 2170-EZSS-450 | EAR99 | 3926.90.9985 | 1 | ||||||||||||||||||||||||||||||||||||
![]() |
TL50WGBRQ | - | ![]() |
4796 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Obsolete | -20°C ~ 50°C | Complete Unit | - | TL50WG | IP67 - Dust Tight, Waterproof | Connector | - | 18 ~ 24VAC, 30VDC | - | Not Applicable | REACH Unaffected | OBSOLETE | 1 | LED | 4 | Blue, Green, Red, White | Steady | - | |||||||||||||||||||||||||||||
![]() |
WLS27CWGRYB5-1130DS24Q | 711.0000 | ![]() |
7 | 0.00000000 | Banner Engineering Corporation | WLS27 | Box | Active | -40°C ~ 70°C | Cascadable | WLS27CWG | CE, cULus | IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof | 44.49" (1130.0mm) | - | Connector (M12) | 12 ~ 30VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8539.52.0091 | 1 | Aluminum (Al) | Tubular, Diffused | Red, Green, Blue, Yellow, White | 740lm Red, 16000lm Green, 500lm Blue, 2280lm Yellow, 2600lm White | 1.06" (27.0mm) Dia | - | |||||||||||||||||||||||||
![]() |
WLS28-2XWG-570GSQ | 491.0000 | ![]() |
1510 | 0.00000000 | Banner Engineering Corporation | WLS28-2 | Box | Active | -40°C ~ 70°C | - | CE, cULus | IP65/IP67/IP69K - Dust Tight, Water Resistant, Waterproof | 22.44" (570.0mm) | - | Connector (M12) | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | Aluminum (Al) | Flat, Clear | Green, White | 800lm Green, 950lm White | 1.10" x 0.82" (28.0mm x 20.9mm) | - | ||||||||||||||||||||||||||||
![]() |
WLB92XR1100PWMQ | 751.0100 | ![]() |
2969 | 0.00000000 | Banner Engineering Corporation | WLB92 | Box | Active | -40°C ~ 70°C | Dimmable | CE, cULus | IP40 | 43.31" (1100.0mm) | - | Connector (M12) | - | 24VDC | - | Not Applicable | REACH Unaffected | 1 | Aluminum (Al) | Tubular | Red | 1545lm | 3.80" x 4.10" (96.5mm x 104.1mm) | 50,000 Hours | ||||||||||||||||||||||||||||
![]() |
TL50BLZR2AOS3IQP | 319.0000 | ![]() |
4062 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | Adjustable Volume, Alarm | TL50BL | IP67 - Dust Tight, Waterproof | Wire Leads | - | 100 ~ 240VAC | - | Not Applicable | REACH Unaffected | EAR99 | 8531.80.9041 | 1 | LED | 1 | Red | Flashing | Pulse | ||||||||||||||||||||||||||||
![]() |
WLS28-2XWW430DSQ | 311.0000 | ![]() |
7738 | 0.00000000 | Banner Engineering Corporation | WLS28-2 | Box | Active | -40°C ~ 70°C | - | CE, cULus | IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof | 16.93" (430.0mm) | - | Connector (M12) | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | Aluminum (Al) | Flat, Diffused | White, Cool | 1200lm | 1.10" x 0.83" (28.0mm x 21.0mm) | 75,000 Hours | ||||||||||||||||||||||||||||
![]() |
SGSSP4-400Q88 | 1.0000 | ![]() |
4561 | 0.00000000 | Banner Engineering Corporation | SGS | Bulk | Active | 0°C ~ 50°C | - | SGSSP4 | IP65 - Dust Tight, Water Resistant | - | 24VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1 | - | - | 1200mm | 4 | 400mm | 0.5m ~ 30.0m | ||||||||||||||||||||||||||||||
![]() |
WLS28-2XW430L25XPBQ | 282.0000 | ![]() |
2103 | 0.00000000 | Banner Engineering Corporation | WLS28-2 | Box | Active | -40°C ~ 70°C | High/Low/Off Switching | CE, cULus | IP50 - Dust Protected | 16.93" (430.0mm) | - | Connector (M12) | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | Aluminum (Al) | Flat, Clear | White | 900lm | 1.10" x 1.27" (28.0mm x 32.2mm) | 75,000 Hours | ||||||||||||||||||||||||||||
![]() |
TL70ZBOBR | 502.0000 | ![]() |
7234 | 0.00000000 | Banner Engineering Corporation | TL70 | Box | Active | -40°C ~ 50°C | Complete Unit | Dip Switch | TL70ZB | IP65 - Dust Tight, Water Resistant | Wire Leads | - | 100 ~ 240VAC | - | Not Applicable | REACH Unaffected | 1 | LED | 4 | Blue, Orange, Red | Steady | - | ||||||||||||||||||||||||||||||
![]() |
TL50BLGY2R2G | 352.0000 | ![]() |
1852 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | - | TL50BL | IP67 - Dust Tight, Waterproof | Wire Leads | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | EAR99 | 8531.80.9051 | 1 | LED | 4 | Green, Red, Yellow | Flashing | - | ||||||||||||||||||||||||||||
![]() |
TL50BLGWR2BALSCQ | 422.0000 | ![]() |
1011 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | Alarm | TL50BL | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | EAR99 | 8531.80.9041 | 1 | LED | 4 | Blue, Green, Red, White | Flashing | Continuous | ||||||||||||||||||||||||||||
![]() |
TL50BLBY2GR2Q | 352.0000 | ![]() |
7017 | 0.00000000 | Banner Engineering Corporation | TL50 | Box | Active | -20°C ~ 50°C | Complete Unit | - | TL50BL | IP67 - Dust Tight, Waterproof | Connector | - | 24VAC, 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | EAR99 | 8531.80.9051 | 1 | LED | 4 | Blue, Green, Red, Yellow | Flashing | - | ||||||||||||||||||||||||||||
![]() |
WLS28-2CW1130SPWMQ | 608.0000 | ![]() |
8127 | 0.00000000 | Banner Engineering Corporation | WLS28-2 | Box | Active | -40°C ~ 70°C | Cascadable, Dimmable | CE, cULus | IP65/IP67/IP69K - Dust Tight, Water Resistant, Waterproof | 44.49" (1130.0mm) | - | Connector (M12) | - | 12 ~ 30VDC | - | Not Applicable | REACH Unaffected | 1 | Aluminum (Al) | Flat, Clear | White | 3200lm | 1.10" x 0.82" (28.0mm x 20.9mm) | 75,000 Hours |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse