Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number
TES 2N-4810 Traco Power TES 2N-4810 26.8800
RFQ
ECAD 10 0.00000000 Traco Power TES 2N (2W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.36" H (24.0mm x 13.7mm x 9.3mm) Surface Mount 16-SMD Module, 6 Leads Isolated Module SCP TES 2 75V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-2479 EAR99 8504.40.9580 10 1.7 W 1 500mA 36V 71% 3.3V - - - 1.5 kV
TMV 2-1212SHI Traco Power TMV 2-1212SHI 11.6800
RFQ
ECAD 2834 0.00000000 Traco Power TMV 2HI (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 168mA 10.8V 83% 12V - - - 5.2 kV
THM 10-1221 Traco Power THM 10-1221 55.1900
RFQ
ECAD 10 0.00000000 Traco Power THM 10 (10W) Tube Active -40°C ~ 90°C (With Derating) Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 10 CB, cURus 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 2 1A, 1A 9V 84% 5V -5V - - 5 kV
TMR 3-1222 Traco Power TMR 3-1222 22.8600
RFQ
ECAD 19 0.00000000 Traco Power TMR 3 (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2598 EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 9V 83% 12V -12V - - 1.6 kV
TEL 3-2411 Traco Power TEL 3-2411 15.6500
RFQ
ECAD 207 0.00000000 Traco Power TEL 3 (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.79" W x 0.40" H (32.0mm x 20.0mm x 10.2mm) Through Hole 24-DIP Module, 13 Leads Isolated Module SCP TEL 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2709 EAR99 8504.40.9580 10 3 W 1 600mA 18V 77% 5V - - - 1.5 kV
TEN 60-4818WIR Traco Power TEN 60-4818WIR 129.1100
RFQ
ECAD 20 0.00000000 Traco Power TEN 60WIR (60W) Box Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.60" W x 1.00" H (50.8mm x 40.7mm x 25.4mm) Through Hole 8-DIP Module Isolated Module Adjustable Output, Remote On/Off TEN 60 - 75V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TEN60-4818WIR EAR99 8504.40.9580 10 60 W 1 - 1.25A 18V 92% 48V - - - 3 kV
THD 10-2413WIN Traco Power THD 10-2413WIN 30.8100
RFQ
ECAD 10 0.00000000 Traco Power THD 10WIN (10W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP THD 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 666mA 9V 87% 15V - - - 1.5 kV
TES 1-1213V Traco Power TES 1-1213V 10.2900
RFQ
ECAD 8032 0.00000000 Traco Power TES 1V (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.64" L x 0.31" W x 0.31" H (16.3mm x 8.0mm x 8.0mm) Surface Mount 12-SMD Module, 10 Leads Isolated Module SCP TES 1 13.2V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-1898 EAR99 8504.40.9580 10 1 W 1 67mA 10.8V 81% 15V - - - 3 kV
TEP 160-2415 Traco Power TEP 160-2415 220.1300
RFQ
ECAD 52 0.00000000 Traco Power TEP 160 (196W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP TEP 160 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 144 W 1 6A 16.5V 90% 24V - - - 2.25 kV
THD 10-4810WIN Traco Power THD 10-4810WIN 30.8100
RFQ
ECAD 30 0.00000000 Traco Power THD 10WIN (10W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP THD 10 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 8.9 W 1 2.7A 18V 86% 3.3V - - - 1.5 kV
TMR 2-4823WIN Traco Power TMR 2-4823WIN 17.2870
RFQ
ECAD 3418 0.00000000 Traco Power TMR 2WIN (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, OCP, SCP TMR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 2 67mA, 67mA 18V 82% 15V -15V - - 1.5 kV
TBA 1-1213E Traco Power TBA 1-1213E 3.8800
RFQ
ECAD 94 0.00000000 Traco Power TBA 1E (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.39" H (19.5mm x 6.0mm x 10.0mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TBA 1 - 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 990 mW 1 66mA 10.8V 80% 15V - - - 1.5 kV
TRI 6-4822 Traco Power TRI 6-4822 51.0020
RFQ
ECAD 3960 0.00000000 Traco Power TRI 6 (6W) Tube Active -40°C ~ 95°C ITE (Commercial) 1.25" L x 0.80" W x 0.47" H (31.8mm x 20.3mm x 12.0mm) Through Hole 24-DIP Module, 6 Leads Isolated Module - TRI 6 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected TRI6-4822 EAR99 8504.40.9580 10 6 W 2 - 250mA, 250mA 36V 87% 12V -12V - - 9 kV
TEN 10-4815 Traco Power TEN 10-4815 51.8700
RFQ
ECAD 3434 0.00000000 Traco Power TEN 10 (10W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module, 4 Leads Isolated Module OCP, OVP, SCP TEN 10 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 415mA 36V 83% 24V - - - 1.5 kV
TEL 8-4815WI Traco Power TEL 8-4815WI 24.6900
RFQ
ECAD 4 0.00000000 Traco Power TEL 8WI (8W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 0.95" L x 0.55" W x 0.33" H (24.1mm x 14.0mm x 8.5mm) Through Hole 16-DIP Module, 6 Leads Isolated Module SCP TEL 8 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 8 W 1 335mA 18V 86% 24V - - - 1.5 kV
TSV 2415D Traco Power TSV 2415D 15.1860
RFQ
ECAD 2658 0.00000000 Traco Power TSV (1W) Tube Not For New Designs -40°C ~ 85°C ITE (Commercial) 0.60" L x 0.31" W x 0.27" H (15.2mm x 8.0mm x 7.0mm) Surface Mount 22-SMD Module, 10 Leads Isolated Module SCP TSV 2415 26.4V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 900 mW 2 30mA, 30mA 21.6V 80% 15V -15V - - 3 kV
THM 60-2413WI Traco Power THM 60-2413WI 152.7700
RFQ
ECAD 65 0.00000000 Traco Power THM 60WI (60W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm) Through Hole Quarter Brick Isolated Module Adjustable Output, Remote On/Off CB, cURus 36V Quarter Brick - ROHS3 Compliant Not Applicable REACH Unaffected 1951-THM60-2413WI EAR99 8504.40.9580 1 60 W 1 - 4A 9V 90% 15V - - - 5 kV 60601-1; 62368-1
TBA 1-1213 Traco Power TBA 1-1213 3.8800
RFQ
ECAD 175 0.00000000 Traco Power TBA 1 (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.46" L x 0.24" W x 0.40" H (11.7mm x 6.0mm x 10.2mm) Through Hole 4-SIP Module Isolated Module SCP TBA 1 - 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 975 mW 1 65mA 10.8V 80% 15V - - - 1.5 kV
THM 15-2423 Traco Power THM 15-2423 63.3800
RFQ
ECAD 16 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1639 EAR99 8504.40.9580 10 15 W 2 500mA, 500mA 18V 90% 15V -15V - - 5 kV
TDN 1-1210WI Traco Power TDN 1-1210WI 17.2000
RFQ
ECAD 6286 0.00000000 Traco Power TDN 1WI (1W) Tube Active -40°C ~ 90°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 1 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1 W 1 300mA 4.5V 77% 3.3V - - - 1.6 kV
TSR 1-2450SM Traco Power TSR 1-2450SM 9.9700
RFQ
ECAD 7890 0.00000000 Traco Power TSR 1SM Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.60" L x 0.37" W x 0.30" H (15.2mm x 9.3mm x 7.6mm) Surface Mount 10-SMD Module, 6 Leads Linear Regulator Replacement SCP TSR 1 36V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-2524 EAR99 8504.40.9580 10 5 W 1 1A 6.5V 94% 5V - - -
TRN 3-4815 Traco Power TRN 3-4815 20.3400
RFQ
ECAD 3710 0.00000000 Traco Power TRN 3 (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.30" W x 0.43" H (11.9mm x 7.7mm x 11.0mm) Through Hole 5-SIP Module, 4 Leads Isolated Module SCP TRN 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 125mA 36V 82% 24V - - - 1.6 kV
THM 10-0522 Traco Power THM 10-0522 55.1900
RFQ
ECAD 15 0.00000000 Traco Power THM 10 (10W) Tube Active -40°C ~ 90°C (With Derating) Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 10 CB, cURus 9V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 2 416mA, 416mA 4.5V 85.5% 12V -12V - - 5 kV
TSH 1205S Traco Power TSH 1205S 17.5390
RFQ
ECAD 1684 0.00000000 Traco Power TSH (2W) Tube Not For New Designs -40°C ~ 85°C ITE (Commercial) 0.50" L x 0.37" W x 0.36" H (12.7mm x 9.3mm x 9.2mm) Surface Mount 14-SMD Module, 5 Leads Isolated Module SCP TSH 1205 13.2V - download ROHS3 Compliant 3 (168 Hours) REACH Unaffected EAR99 8504.40.9580 10 2 W 1 400mA 10.8V 78% 5V - - - 1 kV
TES 2-0511M Traco Power TES 2-0511M 29.8200
RFQ
ECAD 1000 0.00000000 Traco Power TES 2M (2W) Tube Active -25°C ~ 80°C (With Derating) ITE (Commercial), Medical 0.94" L x 0.54" W x 0.36" H (24.0mm x 13.7mm x 9.3mm) Surface Mount 16-SMD Module, 6 Leads Isolated Module SCP TES 2 5.5V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-2463 EAR99 8504.40.9580 10 2 W 1 400mA 5V 66% 5V - - - 4 kV
THM 60-2422WI Traco Power THM 60-2422WI 160.4600
RFQ
ECAD 5 0.00000000 Traco Power THM 60WI (60W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm) Through Hole Quarter Brick Isolated Module Adjustable Output, Remote On/Off CB, cURus 36V Quarter Brick - ROHS3 Compliant Not Applicable REACH Unaffected 1951-THM60-2422WI EAR99 8504.40.9580 1 60 W 2 - 2.5A, 2.5A 9V 89% 12V -12V - - 5 kV 60601-1; 62368-1
TRS 2-1213 Traco Power TRS 2-1213 16.0800
RFQ
ECAD 24 0.00000000 Traco Power TRS 2 (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module, 6 Leads Isolated Module SCP TRS 2 18V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-2052 EAR99 8504.40.9580 10 2 W 1 134mA 9V 83% 15V - - - 1.6 kV
TDR 2-4811 Traco Power TDR 2-4811 27.3000
RFQ
ECAD 4757 0.00000000 Traco Power TDR 2 (2W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Through Hole 14-DIP Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 400mA 36V 81% 5V - - - 1.6 kV
THD 10-2411WIN Traco Power THD 10-2411WIN 30.8100
RFQ
ECAD 18 0.00000000 Traco Power THD 10WIN (10W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP THD 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 2A 9V 85% 5.1V - - - 1.5 kV
TMR 6-4822WIR Traco Power TMR 6-4822WIR 33.6100
RFQ
ECAD 10 0.00000000 Traco Power TMR 6WIR (6W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, OCP, SCP TMR 6 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 6 W 2 250mA, 250mA 18V 87% 12V -12V - - 3 kV