Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Voltage - Input (Min) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TEQ 100-4818WIR | 391.4900 | ![]() |
2 | 0.00000000 | Traco Power | TEQ 100WIR (100W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 100 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 101W | 1 | 2.1A | 19V | 90% | 48V | - | - | - | 2.25 kV | |||||||||
![]() |
TEQ 160-4815WIR | 444.0500 | ![]() |
2 | 0.00000000 | Traco Power | TEQ 160WIR (160W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 160 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 156W | 1 | 6.5A | 19V | 90% | 24V | - | - | - | 2.25 kV | |||||||||
![]() |
TEQ 160-4818WIR | 444.0500 | ![]() |
2138 | 0.00000000 | Traco Power | TEQ 160WIR (160W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 160 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 154W | 1 | 3.2A | 19V | 90% | 48V | - | - | - | 2.25 kV | |||||||||
![]() |
TEQ 160-7218WIR | 472.7100 | ![]() |
2828 | 0.00000000 | Traco Power | TEQ 160WIR (160W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 160 | CB, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 182W | 1 | 3.8A | 43V | 89% | 48V | - | - | - | 2.25 kV | |||||||||
![]() |
TEQ 300-7218WIR | 731.8500 | ![]() |
1 | 0.00000000 | Traco Power | TEQ 300WIR (300W) | Box | Active | -40°C ~ 80°C | Industrial, ITE (Commercial), Railway | 6.00" L x 4.00" W x 1.52" H (152.4mm x 101.6mm x 38.6mm) | Chassis Mount | Enclosed | TEQ 300 | CB, CE, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 302W | 1 | 6.3A | 43V | 92% | 48V | - | - | - | 3 kV | |||||||||
TMDC 20-4811 | 68.0300 | ![]() |
1213 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 4A | 18V | 90% | 5.1V | - | - | - | 2.5 kV | ||||||||||
![]() |
TMDC 20-4818 | 67.3800 | ![]() |
10 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 420mA | 18V | 89% | 48V | - | - | - | 2.5 kV | |||||||||
![]() |
TMDC 60-4812 | 89.6800 | ![]() |
10 | 0.00000000 | Traco Power | TMDC 60 (60W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 4.41" L x 2.67" W x 1.50" H (112.0mm x 67.8mm x 38.1mm) | Chassis Mount | Enclosed | TMDC 60 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 60W | 1 | 5A | 18V | 92% | 12V | - | - | - | 2.5 kV | |||||||||
![]() |
TML 100-148C | 165.4500 | ![]() |
1 | 0.00000000 | Traco Power | TML 100C (85-100W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.60" L x 2.48" W x 1.46" H (142.2mm x 63.0mm x 37.1mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | TML 100 | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 101W | 1 | 93% | 48V | - | - | - | - | - | Yes | 3 kV | 2.1 A | ||||||
![]() |
TML 20215C | 68.2400 | ![]() |
6 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.15" W x 1.09" H (96.0mm x 54.6mm x 27.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 20215 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 2 | 84% | 15V | -15V | - | - | - | - | No | 3 kV | 667 mA | 667 mA | |||||
![]() |
TMM 24105C | 80.4600 | ![]() |
4 | 0.00000000 | Traco Power | TMM 24 (24W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 24105 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 77% | 5V | - | - | - | - | - | No | 4 kV | 3 A | ||||||
![]() |
TMM 24212C | 82.5500 | ![]() |
16 | 0.00000000 | Traco Power | TMM 24 (24W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 24212 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 24W | 2 | 84% | 12V | -12V | - | - | - | - | No | 4 kV | 1 A | 1 A | |||||
![]() |
TMM 40124C | 93.8600 | ![]() |
50 | 0.00000000 | Traco Power | TMM 40 (40W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.41" L x 2.51" W x 1.34" H (112.0mm x 63.8mm x 34.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 40124 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 40W | 1 | 84% | 24V | - | - | - | - | - | No | 4 kV | 1.66 A | ||||||
![]() |
TMM 60112C | 110.0600 | ![]() |
2 | 0.00000000 | Traco Power | TMM 60 (60W) | Box | Active | -40°C ~ 75°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.41" L x 2.57" W x 1.50" H (112.0mm x 65.3mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 60112 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 5 | 60W | 1 | 87% | 12V | - | - | - | - | - | No | 4 kV | 5 A | ||||||
![]() |
TMP 30317C | 88.4500 | ![]() |
3 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.41" L x 2.51" W x 1.01" H (112.0mm x 63.8mm x 25.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 30317 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 29W | 3 | 71% | 5V | 3.3V | 12V | - | - | - | Yes | 3 kV | 4.5 A | 1 A | 250 mA | ||||
![]() |
TPI 150-136A-J | 83.4100 | ![]() |
2 | 0.00000000 | Traco Power | TPI 150A (150W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.16" H (101.6mm x 50.8mm x 29.5mm) | Chassis Mount | Open Frame | Adjustable Output, PFC, Universal Input | TPI 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 36V | - | - | - | - | - | No | 3 kV | 4.17 A | ||||||
![]() |
TPI 150-148A-J | 83.4100 | ![]() |
293 | 0.00000000 | Traco Power | TPI 150A (150W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.16" H (101.6mm x 50.8mm x 29.5mm) | Chassis Mount | Open Frame | Adjustable Output, PFC, Universal Input | TPI 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 48V | - | - | - | - | - | No | 3 kV | 3.13 A | ||||||
![]() |
TPP 150-115 | 121.4200 | ![]() |
2 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 15V | - | - | - | - | - | No | 4 kV | 10 A | ||||||
![]() |
TPP 150-124 | 121.4200 | ![]() |
20 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 24V | - | - | - | - | - | No | 4 kV | 6.25 A | ||||||
![]() |
TPP 150-128 | 121.4200 | ![]() |
4286 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 28V | - | - | - | - | - | No | 4 kV | 5.36 A | ||||||
TPP 40-148A-J | 49.6000 | ![]() |
4680 | 0.00000000 | Traco Power | TPP 40A (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 0.94" H (76.2mm x 50.8mm x 23.9mm) | Chassis Mount | Open Frame | Universal Input | TPP 40 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 92% | 48V | - | - | - | - | - | No | 4 kV | 840 mA | |||||||
![]() |
TPP 40-221 | 90.1000 | ![]() |
9957 | 0.00000000 | Traco Power | TPP 40 (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TPP 40 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 60W | 2 | 89% | 12V | 5V | - | - | - | - | No | 4 kV | 3.34 A | 4 A | |||||
![]() |
TXH 120-148 | 104.7400 | ![]() |
4 | 0.00000000 | Traco Power | TXH 120 (120W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.39" L x 3.23" W x 1.50" H (136.9mm x 82.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Universal Input | TXH 120 | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 92% | 48V | - | - | - | - | - | No | 4 kV | 2.5 A | ||||||
![]() |
TXH 480-148 | - | ![]() |
3289 | 0.00000000 | Traco Power | TXH 480 (480W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 7.98" L x 4.19" W x 1.77" H (202.8mm x 106.5mm x 45.0mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Universal Input | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 91% | 48V | - | - | - | - | - | No | 3 kV | 10 A | |||||||
![]() |
TXH 600-112 | - | ![]() |
2466 | 0.00000000 | Traco Power | TXH 600 (600W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 9.00" L x 4.13" W x 1.73" H (228.5mm x 105.0mm x 44.0mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 10 | 540W | 1 | 90% | 12V | - | - | - | - | - | Yes | 3 kV | 45 A | |||||||
![]() |
TXL 035-3.3S | 52.0900 | ![]() |
5 | 0.00000000 | Traco Power | TXL 035 (35W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 3.90" L x 3.23" W x 1.38" H (99.1mm x 82.0mm x 35.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXL 035 | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 30W | 1 | 84% | 3.3V | - | - | - | - | - | Yes | 3 kV | 9 A | ||||||
![]() |
TXL 100-15S | - | ![]() |
4712 | 0.00000000 | Traco Power | TXL 100 (100W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 7.80" L x 3.74" W x 1.50" H (198.1mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 105W | 1 | 84% | 15V | - | - | - | - | - | Yes | 3 kV | 7 A | |||||||
![]() |
TXL 100-48S | - | ![]() |
7789 | 0.00000000 | Traco Power | TXL 100 (100W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 7.80" L x 3.74" W x 1.50" H (198.1mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 110W | 1 | 84% | 48V | - | - | - | - | - | Yes | 3 kV | 2.3 A | |||||||
![]() |
TXL 350-48S | - | ![]() |
2729 | 0.00000000 | Traco Power | TXL 350 (350W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 8.35" L x 4.53" W x 1.97" H (212.1mm x 115.1mm x 50.0mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Remote Sense, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 360W | 1 | 84% | 48V | - | - | - | - | - | Yes | 3 kV | 7.5 A | |||||||
![]() |
TZL 060-2412 | 89.9000 | ![]() |
7999 | 0.00000000 | Traco Power | TZL (60W) | Box | Not For New Designs | -10°C ~ 60°C (With Derating) | ITE (Commercial) | 6.26" L x 3.74" W x 1.50" H (159.0mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | TZL 060 | - | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 60W | 1 | 5A | 18V | 80% | 12V | - | - | - | 1.5 kV |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse